Home ProductsIE2 Motor

IE2 MS Asynchronous Motor, 0.75KW-11KW AC Motor 3 Phase Electric Motor

Good quality Peripheral Water Pump for sales
Good quality Peripheral Water Pump for sales
Zhongzhi does really good on the design and manufacturing of the products. Experienced engineers service us very nice.

—— Vadim Zabiiaka

Good quality, great manufacturers, we are happy with your products.

—— Mr.Reuben kimwolo

Have been working together for more than 3 years very professional. all products work fine in our types of equipment. Thank you.

—— Mr.Yılmaz Türkoğlu

Thank you so much for Zhongzhi company to make our project run smoothly.

—— Mehmet Sefa KEÇİK

Technical issues resolved, reputation is very good.

—— Mr.ANTONIS GKANIS

I'm Online Chat Now

IE2 MS Asynchronous Motor, 0.75KW-11KW AC Motor 3 Phase Electric Motor

China IE2 MS Asynchronous Motor, 0.75KW-11KW AC Motor 3 Phase Electric Motor supplier
IE2 MS Asynchronous Motor, 0.75KW-11KW AC Motor 3 Phase Electric Motor supplier

Large Image :  IE2 MS Asynchronous Motor, 0.75KW-11KW AC Motor 3 Phase Electric Motor

Product Details:

Place of Origin: FUAN CHINA
Brand Name: ZOZHI
Certification: CE,ISO
Model Number: IE2 MS100L2-4

Payment & Shipping Terms:

Minimum Order Quantity: 10pcs
Price: negotiated
Packaging Details: Packed in cartons,veneer case or wooden case.
Delivery Time: 25 working days after received your payment
Payment Terms: T/T
Supply Ability: 10000pcs/month
Contact Now
Detailed Product Description
Name: IE2 Motor Output: 3kw/4Hp
Voltage: 230/400V/60HZ Winding Material: 100% Copper Wire
Standard: IEC 2 Housing: Aluminum
Pole: 4 Phase: 3 Phase

IE2 MS Asynchronous Motor, 0.75KW-11KW AC Motor 3 Phase Electric Motor

 

Description

 

Output Range: 0.75KW~11KW
Voltage: 415V/380V/660V/as required
Frequency: 50Hz/60Hz/as required
No. of Poles: 2, 4, 6
Speed: 1000rpm~3000rpm
Protection class: IP44 / IP54 / IP55
Insulation class: B / F
Connection: Y/D
Altitude: less than 1000 meter
Working temperature: -15°C~40°C
Duty type: S1
Cooling method: IC411

Mounting styles: B3 / B5 / B35

*B3 Frame with foot end, shield without flange

*B35 Frame with foot end, shield with flange
*B5 Frame without foot end, shield with flange.workshop

 

Features of 3 phase 
asynchronous 
induction motor
Self-starting, Robust in construction
Economical, Easier to maintain.
Less armature reaction and brush sparking because of the absence of commutators and brushes that may cause sparks.

 

three phase induction motor IE2


Application

Three-phase asynchronous motors have higher operating efficiency and better working characteristics. They run at a nearly constant speed from no-load to the full-load range and can meet the transmission requirements of most industrial and agricultural production machinery. Asynchronous motors are widely used in driving machine tools, water pumps, blowers, and compressors.

three phase induction motor


Operating conditions
Ambient temperature: -15°C~40°C
Altitude: Altitude should be higher than 1000 meters above sea level.
Rated voltage: 380V,400V,415V,440V. Rated frequency: 50Hz,60Hz.
Connection: Y Star-connection for 3kw or less whereas and delta-connection.
Duty/Rating: Continuous (S1)
Insulation class: F, the temperature rise of the stator winding is examined at 80K
(by resistance method).
Protection class: IP55.
Cooling method: IC411.

 
Production Line
three phase induction motor


 
Technical Data

 

Model Power (V) (A) (r/min) Eff.(%) P.F. Ist/In Tmax/Tn
Kw HP 50% 75% 100%
IE2 MS801-2 0.75 1 230/400 3.0/1.73 2800 76.5 77.3 77.4 0.813 2.2 2.3
IE2 MS802-2 1.1 1.5 4.2/2.43 2800 79 80 79.6 0.825 2.2 2.3
IE2 MS90S-2 1.5 2 5.53/3.19 2820 80.2 81.5 81.3 0.837 2.2 2.3
IE2 MS90L-2 2.2 3 7.93/4.58 2820 82.2 83.5 83.2 0.837 2.2 2.3
IE2 MS100L-2 3 4 10.5/6.06 2830 84 85.1 84.6 0.848 2.2 2.3
IE2 MS112M-2 4 5.5 400/690 7.97/4.6 2850 85.4 86.8 85.8 0.848 2.2 2.3
IE2 MS132S1-2 5.5 7.5 10.65/6.15 2870 86.7 87.3 87 0.86 2 2.3
IE2 MS132S2-2 7.5 10 14.35/8.28 2870 87.6 88.3 88.1 0.86 2 2.3
IE2 MS160M1-2 11 15 20.74/11.97 2900 89 89.8 89.4 0.86 2 2.3
IE2 MS160M2-2 15 20 27.99/16.16 2900 90 90.5 90.3 0.86 2 2.3
IE2 MS160L-2 18.5 25 33.83/19.53 2900 90.3 91 90.9 0.872 2 2.2
IE2 MS802-4 0.75 1 230/400 3.28/1.9 1380 77.3 79.8 79.6 0.72 2.3 2.3
IE2 MS90S-4 1.1 1.5 4.57/2.64 1400 79.9 81.7 81.4 0.743 2.3 2.3
IE2 MS90L-4 1.5 2 6.02/3.48 1400 82.1 83.5 82.8 0.755 2.3 2.3
IE2 MS100L1-4 2.2 3 8.42/4.86 1420 82.6 84.5 84.3 0.778 2.2 2.3
IE2 MS100L2-4 3 4 11.32/6.54 1420 84.2 85.7 85.5 0.778 2.2 2.3
IE2 MS112M-4 4 5.5 400/690 8.47/4.89 1430 85.8 87 86.6 0.79 2.2 2.3
IE2 MS132S-4 5.5 7.5 11.18/6.45 1450 87.4 88.3 87.7 0.813 2.2 2.3
IE2 MS132M-4 7.5 10 14.85/8.58 1450 88.2 89 88.7 0.825 2.2 2.3
IE2 MS160M-4 11 15 21.84/12.61 1460 89.1 90 89.8 0.813 2.2 2.3
IE2 MS160L-4 15 20 29.08/16.79 1460 90.2 91.1 90.6 0.825 2.2 2.3
IE2 MS90S-6 0.75 1 230/400 3.82/2.2 910 73.4 76.3 75.9 0.65 2 2.2
IE2 MS90L-6 1.1 1.5 5.25/3.03 910 77 78.8 78.1 0.673 2 2.2
IE2 MS100L-6 1.5 2 6.77/3.91 940 79.6 80.8 79.8 0.697 2 2.2
IE2 MS112M-6 2.2 3 9.69/5.59 940 80.4 81.6 81.8 0.697 2 2.2
IE2 MS132S-6 3 4 12.56/7.25 960 81 83.4 83.3 0.72 2 2.2
IE2 MS132M1-6 4 5.5 400/690 9.36/5.4 960 82.7 84.5 84.6 0.732 2 2.2
IE2 MS132M2-6 5.5 7.5 12.47/7.2 960 84.8 86.2 86 0.743 2 2.2
IE2 MS160M-6 7.5 10 16.78/9.69 970 86.4 87.5 87.2 0.743 2 2
IE2 MS160L-6 11 15 24.19/13.97 970 88.2 89.2 88.7 0.743 2 2

 


Performance comparison chart:

ELECTRIC MOTOR EFFICIENCY VALUES-4POLES 1500 RPM
Power(kw) eff2 (nominal) eff1 (nominal) IE2 (nominal) IE3 (nominal)
0.75 - - 79.6 82.5
1.1 76.2 83.8 81.4 84.1
1.5 78.5 85.0 82.8 85.3
2.2 81 86.4 84.3 86.7
3.0 82.6 87.4 85.5 87.7
4.0 84.2 88.3 86.6 88.6
5.5 85.7 89.2 87.7 89.6
7.5 87 90.1 88.7 90.4
11 88.4 91.0 89.8 91.4
15 89.4 91.8 90.6 92.1
18.5 90 92.2 91.2 92.6
22 90.5 82.6 91.6 93.0
30 91.4 93.2 92.3 93.8
37 92 93.6 92.7 93.9
45 92.5 93.9 93.1 94.2
55 93 94.2 93.5 94.6
75 93.6 94.7 94.0 95.0
90 93.9 95.0 94.2 95.2
110     94.5 95.4
132     94.7 95.6
160     94.9 95.8
200...375     95.1 96.0

 

Common Faults With AC Motors

 

We often see the same faults with AC motors, below and some of the most common faults with AC motors and how you can identify them.

 

Fault Notice
Open Circuit on Windings Motor Buzzes or Hums and won’t work
Earth Fault Motor Dead and won’t work
Bearing Failing Noise, Vibration, Excess Heat on Drive End or Non-Drive End
Bearing Collapse Shaft Damage, Core Damage, Winding Damage
Rotor Problems Movement in Shaft, Bearing Journals undersized.
Misalignment Premature Coupling Failures, Vibration of Motor
Bent Shaft Premature Bearing Failures, Vibration
 

asynchronous motor

IE2 MS Asynchronous Motor, 0.75KW-11KW AC Motor 3 Phase Electric Motor

 

Features of 3 phase 
asynchronous 
induction motor
Self-starting, Robust in construction
Economical, Easier to maintain.
Less armature reaction and brush sparking because of the absence of commutators and brushes that may cause sparks.