speed reducer use skill

October 10, 2019

speed reducer use skill

 

1. After 200~300 hours of operation, you should change the oil for the first time. In future use, you should check the quality of the oil regularly. For the mixed impurities or deteriorated oil, you must replace it in time. Under normal circumstances, for long-term continuous operation of the reducer, you should replace the new oil by 5000 hours of operation or once a year. The gearbox that has been deactivated for a long time should be replaced with new oil before re-running. The reducer should be added with the same oil as the original grade and should not be mixed with different oil grades. The oils with the same grade and different viscosity are allowed to be mixed;

 

2. When changing oil, wait for the reducer to cool down without burning danger, but still keep warm because after the complete cooling, the viscosity of the oil increases, and it is difficult to drain. Note: you should cut off the power supply of the transmission to prevent unintentional energization;

 

3. During work, when the temperature rise of the oil exceeds 80 °C or the temperature of the oil pool exceeds 100 °C and abnormal noise is generated, stop using it. Check the cause, remove the fault, and replace the lubricating oil before continuing operation. ;

 

4. The user should have reasonable rules for use and maintenance. The operation of the reducer and the problems found in the inspection should be carefully recorded. The above provisions should be strictly implemented.

 

 

registered the trademark "ZOZHI."

 

Add:No.155 Shangcun Qinxiyang Industry Zone,Fuan city,Fujian,China

Tel:+86 0593 6532656 Fax: +86 0593 6531158

Mobile: +86.137.0604.0131

E-mail: sales@zz-pump.com

Website: www.zz-pump.com

www.electricmotorwaterpump.com